2.44m Alfablocs must only be lifted
with an approved lifting attachment or with a suitable
lifting chain if lifting loops are to be used in accordance
with safety instructions.
|
|
 |
|
 |
| |
Once secured to the forklift tines,
the
lifting attachment is inserted into the hollow of the
A to lift the Alfabloc.
N.B. 3.05m & 3.65m are designed
to be lifted using the horizontal cross member 1.4m
above the base of the block and therefore no attachment
is required
|
|
 |
|
 |
| |
Alfablocs are delivered upright on
a flatbed vehicle.

N.B. Some Alfablocs will be
delivered without steel connecting straps fitted.
|
|
 |
|
 |
| |
These strapless units should always
be used to begin installation of each new row of Alfablocs.
This allows the first Alfabloc in a row to be placed
flat against a retaining wall.
|
|
 |
|
 |
| |
Always lift Alfablocs into position
with the connecting straps facing away from the forklift
i.e. towards the installed units.
|
|
 |
|
 |
| |
Align the Alfabloc with the previously
installed unit.
|
|
 |
|
 |
| |
Lift the Alfabloc approximately 450mm
from ground level to enable you to lower it into place
over installed unit.
|
|
 |
|
 |
| |
Once in position lower the Alfabloc
into place so that the connecting straps fit securely
over the installed unit.
NB: DO NOT attempt to install Alfablocs
by inserting the unstrapped end of one unit into the
strapped end of an installed unit. Alfabloc must always
be lowered into place as described above.
|
|
 |
|
 |
| |
To secure Alfablocs in place, first
loosen the bolts in the 2 connecting straps of the freshly
installed unit.
|
|
 |
|
 |
| |
Align the holes in the front edge of
the connecting straps with the holes in the previously
installed unit. Insert bolts and tighten to secure the
Alfabloc in place.
|
|
 |
|
 |
| |
Re-tighten the previously loosened
bolts in the newly installed unit.
|
|
 |
|
 |
| |
Repeat the process (steps 5-11) until
the desired number of units are installed in each row.
|
|
|
|
 |
| |
Attach steel end cover, if required,
by bolting into the holes in the last unit installed
in each row.
|
|
 |
|
|
 |
| |
Alfablocs fitted with corner sections
are moved into position the same way as normal blocks
fitted with
connecting straps.

|
|
 |
|
 |
| |
Position the corner unit against an
existing Alfabloc wall and lower into position.
|
|
 |
|
 |
Instructions For
Handling & Installation
|
|